Click here to find out how to access this document
Dynamic performance requirements for permanent grandstands subject to crowd action. Recommendations for management design and assessment
Publication Year
2008
Document Status
Current
Abstract
Applies to permanent grandstands with seating decks constructed in structural steel, reinforced or prestressed concrete and combinations of these forms of construction. Relates solely to dynamic action from crowd activity. Relevant for grandstands with seating decks of a supported span greater than 6m or cantilever spans of more than 2.5m. Addresses management’s role, the requirement for specialist engineering expertise, natural frequencies and other dynamic properties, testing, compliance with natural frequency requirements, and design for managed events.
Document History
Supersedes 'Dynamic performance requirements for permanent grandstands subject to crowd action: Interim guidance on assessment and design' (2001) and 'Advisory note - Dynamic testing of grandstands and seating decks' (2002). Produced in collaboration with the Department for Communities and Local Government and the Department for Culture Media and Sport.
ISBN
9781906335120
Publisher Information
Institution of Structural Engineers
The Institution of Structural Engineers publishes authoritative books and technical reports that provide essential, accurate information for structural engineers.
47-58 Bastwick Street
London
IStructE
UK
Website: http://www.istructe.org
Email: mail@istructe.org
Tel: 020 725 4535