Click here to find out how to access this document
BS 6400-1:2016 Specification for installation, exchange, relocation, maintenance and removal of gas meters with a maximum capacity not exceeding 6 m³/h. Low pressure (2nd family gases)
Publication Year
2016
Document Status
Current
Abstract
Applicable to primary and secondary meter installations supplied with 2nd family gases from low pressure gas distribution systems with a maximum operating pressure not exceeding 75 mbar, a design minimum pressure of 19 mbar and a design maximum incidental pressure of 200 mbar; only fitted downstream of the emergency control valve; that uses a primary meter regulator downstream of the emergency control valve and where the operating pressure at the outlet of the meter is nominally 21 mbar. Gives requirements for installation, exchange, relocation, maintenance and removal.
Document History
Supersedes BS 6400-1:2006. BS 6400 first published January 1985. Second edition, March 1997. BS 6400-1 first published September 2002. Second edition, July 2006. Third (present) edition, June 2016. Came into effect 30 June 2016.
ISBN
9780580827747
Publisher Information
British Standards Institution
With over 100 years of experience the British Standards Institute is recognised as the UK’s National standards body. Their committees work with the manufacturing and service industries, government, businesses and consumers to facilitate the production of British, European and International standards.
389 Chiswick High Road
London
BSI
UK
Website: http://www.bsi-global.com/
Email: cservices@bsi-global.com
Tel: 020 8996 9000